HomeMy WebLinkAboutNOI 200 Parker RoadA.GENERAL NOTES1. All work and materials shall conform with state and local codes and regulations, and shall be in accordance with good construction standards;2. All dimensions to face of stud unless otherwise noted;3. Verify all dimensions prior to ordering materials and/ or fabrication. Do not scale off drawings. Notify architect of any discrepancies in the plans prior to constructing areas in question.B.SITE WORKS1. Excavation & Grading: Excavate for new foundation. Remove all excess soil. Grade surface to direct water away from house. Final finish grading, screened loam and seed, retaining walls, walkways, paving, gravel driveway, and finish landscaping shall be under separete contract. C.FLOOR CONSTRUCTION1. Joists:As noted on framing plan. Galvanized joist and beam hangers for flush framing. Bridging or solid blocking rows between joists every 6 ft.(maximum). (Refer to Table R602,3(1)Fastener Schedule for Structural Members) Joists and hangers designed by others;2. Decking: 3/4" T&G CDX plywood or "Advantek" decking glued and nailed to framing. Use 1/2" underlayment board under thin-set tile and VCT. Glue and nail underlayment to subfloor;3. Insulate: Floors above unconditioned space to min R-30 using closed cell spray foam or per HERS RATER specifications;4. Finish flooring: As per plan or Owner's selection.D.WALL CONSTRUCTION1. Studs: No.2 2x6 KD spruce (SPF) studs @ 16" on center for all exterior wall construction. Interior partitions to be framed with 2x4 studs @ 16" on center, except where indicated, - Refer to Table R602,3(1) Fastener Schedule for Structural Members;2. Top Plates: Cap walls with double top plate overlapped at corners and intersection with bearing partitions;3. Sheathing: Install 1/2" exterior grade CDX plywood sheathing, nailed according to requirements of Table R602,3(2) Fastener Schedule for Structural Members. Apply building wrap ("Typar" or "Tyvek") on all exterior wall. Tape seams and apply double coverage at all corners. Alternatively, use "zip wall" sheathing and joint tape system;4. Siding: Remove all existing siding on entire home. Prepare for new siding to replace existing. New siding per Owner's selection;5. Trimboards, casing, and soffits: Per Owner's selection;6. Thermal barrier: Insulate exterior walls with closed cell spray foam to min. R-30. Insulate interior walls around bathrooms, and all unheated spaces with fiberglass acoustical batts. Insulate all box headers and corner stud framing;7. Finish: Install 1/2" Blueboard & plaster, prep, primed and painted with 2 finish coats (Colors selected by Owner).E. ROOF CONSTRUCTION:1. Framing: See roof framing plans;2. Ties: Install hurricane ties on each truss and rafter tall and each ridge seat with min. 365# uplift capacity (Simpson' 18 ga. H2.5 hurricane ties, or equal);3. Sheathing: 5/8" exterior grade plywood sheathing nailed per Table R602,3(1) Fastener Schedule for Structural Members. Nail edges at 6" o.c. along gable ends. Alternatively use zip roof sheathing and joint tape system;4. Roof Shingles: Install lifetime "Architectural" asphalt, 3 tab roof shingles over 30# felt paper. Verify manufacture's warranty-color to match existing roof;5. Ice & Water Shield in valleys, over lower 3'-0" of roof edge over all slops with a pitch of less than 4 in 12 and minimum 12" up face of cheek wall;6. Trim: Match existing. Verify with Owner;7. Soffits and Porch ceiling: Composite trim boards, panels or beadboard per Owner's selection;8. Insulation: Insulate roof to min R-60 using closed cell spray foam insulation or per HERS RATER specifications;9. Finish: Install 1x3 strapping @ 16" on center and 4 mill poly vapor barrier. Install 1/2" Blueboard & veneer plaster. Prep and prime. Apply 2 finish coats. (Colors selected by Owner).F. DOORS AND WINDOWS:1. Windows:(Refer to window schedule) Window and ext. doors shall be Energy Star rated and qualify for Federal Tax Credits. Install pre-finished aluminum cap flashing on windows and 6" wide "Vycor" membrane flashing around entire opening sealed to nailling flange and sheathing window openings. Install bituthane membrane pan flashing at sill;2. Door sizes: Shall be as noted on plans and be approved by Owner;3. Wind Pressure Rating: All exterior windows and doors to have min. 30 DP rating, which meet or exceed local wind pressure exposure ratings. Selected manufacturers shall provide product test documentation verifying compliance prior to ordering materials;4. Exterior Doors: (see window schedule for exterior glass doors);5. Interior Doors: Refer to plans for sizing. Owner to approve material, style, and finish.G. INTERIOR MILLWORK:1. Trim: Install paint grade window and door casings, and baseboard to match existing;2. Stairs: Hardwood railing and treads, and painted risers on all finished interior stairs.H. MECHANICAL, ELECTRICAL & FIRE PROTECTION:1. HVAC & Plumbing: Review heating system options with owner. Provide all piping, ductwork and fittings as per code. Fixtures and faucets shall be approved by Owner;2. Electrical: Review electrical options with Owner, install electrical, communication, outlets, switches, lighting, CAT 5 cable and TV jacks as directed by Owner;3. Light Fixtures: Electrical contractor shall furnish all equipment and fixtures. Final locations of all fixtures to be approved by Owner;4. Smoke, Heat and CO Detectors: Install hard wired smoke detectors, carbon monoxide and heat detectors as required by the local fire department.OUTLINE CONSTRUCTION SPECIFICATIONS:THE DRAWING REPRESENT CONSTRUCTION IN SCALE BUT DO NOT "SCALE" DRAWINGS TO OBTAIN MISSING INFORMATION OR TO INTERPRET ANY INFORMATION NOT SPECIFICALLY DIMENSIONED FOR EXACT DETAILING, FABRICATION OR CONSTRUCTION PURPOSES. CONTACT THE DESIGNENGINEER FOR ANY REQUIRED MISSING DIMENSIONS.THE CONTRACTOR SHALL OBTAIN ALL PERMITS FROM THE BUILDING DEPARTMENT PRIOR TO THE START OF WORK.THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK. VERIFY AND CONFIRM ALL DIMENSIONS,ELEVATIONS AND LOCATIONS OF EXISTING BUILDINGS AND OTHER STRUCTURES PRIOR COMMENCING THE WORK. DISCREPANCIES SHALL BE REPORTED TO THE DESIGN ENGINEER IMMEDIATELY, BEFORE PROCEEDING.THE CONTRACTOR ARE RESPONSIBLE FOR ACCURATE COORDINATION OF ALL RELATED PROJECT DRAWINGS, INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, STRUCTURAL, CIVIL AND UTILITIES DRAWINGS. THECONTRACTOR SHALL VERIFY ALL DETAILS, DIMENSIONS AND SYSTEMS PRIOR WORK OR ORDERING ANY ITEM AND COORDINATE WITH THE ARCHITECT OR THE RELATED ENGINEER. DO NOT COMMENCE WORK UNTIL CONDITION IS RESOLVED AND MODIFICATION IF NEEDED ISAPPROVED. ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES THAT MAY EXIST PRIOR TO COMMENCING THE WORK.THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY SHORING AND BRACING REQUIRED FOR PLUMPNESS, STRUCTURAL STABILITY ANDSAFETY WHENEVER REQUIRED TO SUPPORT LOADS AS MAY BE IMPOSED UPON THE STRUCTURE AND ITS COMPONENTS DURING CONSTRUCTION.THE CONTRACTOR SHALL BE COMPLETELY RESPONSIBLE FOR THE SAFETY OF ADJACENT STRUCTURES, PROPERTY, HIS WORKMEN, AND THE PUBLIC, AS AFFECTED BY THE CONSTRUCTION OF THIS PROJECT.THESE DRAWINGS ARE INTENDED TO BE USED ONLY BY EXPERIENCED CONTRACTOR WITH KNOWLEDGE ON THIS TYPE OF WORK. SOULVE PLUS PERSONNEL ARE AVAILABLE TO ANSWER QUESTIONS AND ASSIST THE CONTRACTOR BY EXPLAINING THE DESIGN INTENT.CONTRACTOR SHALL UNDERSTAND THE COMPLEXITIES OF THE PROJECT AND THE CONSTRUCTION SEQUENCE . THE CONTRACTOR ASSUMES TOTAL RESPONSIBILITY FOR ANY CONSEQUENCE OF THAT ACTION.KEY NOTE:JOHNKARAVOLASCIVILNo. 38495COMMONWEALTHOFMASS ACHUS E T TS PR OFESSIONALENGINEER ScaleDateProject(978) 759-7799contact@soulveplus.comwww.soulveplus.comAs indicated1.0COVER SHEET ANDGENERAL NOTESHOME RENOVATION200 PARKER RD, OSTERVILLE-MA07/25/2024200BAS-OST200 PARKER RD - OSTERVILLE - MASSACHUSSETS - 02655BUILDING PERMIT SET - JULY, 25th, 2024PROJECT SCOPE:1.0 HOME RENOVATION;1- ALL WORK SHALL COMPLY WITH STATE AND LOCAL BUILDING CODES AND REGULATIONS2- CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, AND PROCEDURES.3- CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS DURING BUILDING CONSTRUCTION AND SHALL PROVIDE ADEQUATE SHORING AND BRACING TO ENSURE SUCH SAFETY.4- ALL DIMENSIONS AND SITE CONDITIONS SHALL BE FIELD VERIFIED AND SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. NOTIFY THE OWNER OR DESIGNER OF ANY DISCREPANCY PRIOR TO COMMENCEMENT OF WORK.5- IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, AND TO PROTECT THEM FROM DAMAGE.6- ALL DETAILS, SECTIONS, NOTES, OR REFERENCE TO OTHER DRAWINGS ARE INTENDED TO BE TYPICAL. 7- DURING CONSTRUCTION, AND PRIOR TO THE INCORPORATION OF ANY CHANGES, REVISIONS, MODIFICATIONS OR DEVIATION FROM THE CONSTRUCTION DOCUMENT, CONTRACTOR SHALL BRING TO THE ATTENTION OF THE OWNER OR DESIGNER AND OBTAIN APPROVAL FROM THE BUILDING INSPECTOR BEFORE PROCEEDING WITH THE WORK.8- SPECIFIC NOTES AND DETAILS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT.9- GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION.10-CONTRACTOR SHALL PERFORM ALL WORKS IN COMPLIANCE:A- Building: INTERNATIONAL RESIDENTIAL CODE (IRC) 2015 WITH ALL MA AMENDMENTS. Any reference in 780 CMR to the International Residential Code shall be considered reference to 780 CMR 51.00 through 120.00.B- Architectural Access:MASSACHUSETTS ARCHITECTURAL ACCESS BOARD 521-CMR AND THE AMERICANS WITH DISABILITIES ACT (ADAAG), WHERE REQUIRED.C- Mechanical:INTERNATIONAL MECHANICAL CODE (IMC) 2015 WITH 780 CMR - MA MECHANICAL AMENDMENTS.D- Electrical:527 CMR 12.00 (2015 NATIONAL ELECTRICAL CODE) Any reference in 780 CMR to the International Electrical Code shall be considered reference to 527 CMR 12.00: Massachusetts Electrical Code (Amendments).E- Plumbing: 248 CMR MASSACHUSETTS PLUMBING REGULATIONS Reference to the International Plumbing Code shall be considered reference to 248 CMR: Board of State Examiners of Plumbers and Gas Fitters.F- Fire Prevention: INTERNATIONAL FIRE CODE (IFC) AND INTERNATIONALMECHANICAL CODE (IMC) 2015 WITH 527 CMR REGULATIONSAND 780 CMR MA CODE AMENDMENTSG-Energy: 2018 IECC with MA AMENDMENTS."GENERAL NOTES:SITE CONTEXT:SHEET LIST - PERMIT SETNR.NR.NR.NR. SHEET NAMESHEET NAMESHEET NAMESHEET NAME1.0 COVER SHEET AND GENERAL NOTES1.1 EXISTING AND PROPOSED BASEMENT1.2 EXISTING PLANS & PERSPECTIVES1.3 PROPOSED DEMOLITION PLANS & PERSPECTIVES1.4 PROPOSED PLANS & PERSPECTIVES1.5 EXISTING EXTERIOR ELEVATIONS1.6 PROPOSED EXTERIOR ELEVATIONSPROPOSED DOOR SCHEDULEMARK WIDTH HEIGHT LEVELD1 1' - 8" 6' - 8" PROPOSED BASEMENTD2 2' - 8" 6' - 8" PROPOSED BASEMENTD3 2' - 8" 6' - 8" PROPOSED BASEMENTD4 2' - 8" 6' - 8" PROPOSED BASEMENTD5 3' - 0" 7' - 0" GRADED6 9' - 0" 7' - 0" GRADED7 2' - 8" 6' - 8" PROPOSED 1ST FLOORD8 3' - 0" 6' - 8" PROPOSED 1ST FLOORD9 3' - 0" 6' - 8" PROPOSED 1ST FLOORD21 3' - 0" 6' - 8" PROPOSED 1ST FLOORD10 5' - 10" 6' - 5" PROPOSED 1ST FLOORD11 5' - 10" 6' - 5" PROPOSED 1ST FLOORD12 PROPOSED 2ND FLOORD13 2' - 4" 6' - 8" PROPOSED 2ND FLOORD14 2' - 4" 6' - 8" PROPOSED 2ND FLOORD15 2' - 4" 6' - 8" PROPOSED 2ND FLOORD16 2' - 8" 7' - 0" PROPOSED 2ND FLOORD17 3' - 0" 6' - 8" PROPOSED 2ND FLOORD18 3' - 0" 6' - 8" PROPOSED 2ND FLOORD19 5' - 0" 6' - 8" PROPOSED 2ND FLOORD20 6' - 0" 7' - 0" PROPOSED 2ND FLOORPROPOSED WINDOW SCHEDULEMARK WIDTH HEIGHT SILL HEIGHT LEVEL COMMENTSW1 2' - 5" 4' - 3" 2' - 9" GRADEW2 2' - 5" 4' - 3" 2' - 9" GRADEW3 2' - 5" 4' - 3" 2' - 9" GRADEW4 2' - 5" 4' - 3" 2' - 6" PROPOSED 1ST FLOORW5 2' - 5" 4' - 3" 2' - 6" PROPOSED 1ST FLOORW6 2' - 5" 4' - 3" 2' - 6" PROPOSED 1ST FLOORW7 2' - 5 1/2" 5' - 5 1/2" 1' - 3 1/2" PROPOSED 1ST FLOORW8 2' - 5 1/2" 5' - 5 1/2" 1' - 3 1/2" PROPOSED 1ST FLOORW9 2' - 5 1/2" 5' - 5 1/2" 1' - 3 1/2" PROPOSED 1ST FLOORW10 2' - 5 1/2" 5' - 5 1/2" 1' - 3 1/2" PROPOSED 1ST FLOORW11 2' - 7" 3' - 2" 3' - 4" PROPOSED 1ST FLOORW12 2' - 5" 2' - 6" 4' - 3" PROPOSED 2ND FLOORW13 2' - 5" 2' - 6" 4' - 3" PROPOSED 2ND FLOORW14 2' - 5" 2' - 6" 4' - 3" PROPOSED 2ND FLOORW15 2' - 5" 2' - 6" 4' - 3" PROPOSED 2ND FLOORW16 2' - 5" 2' - 6" 4' - 3" PROPOSED 2ND FLOORW17 2' - 5" 4' - 3" 3' - 6" PROPOSED 2ND FLOORW18 2' - 5" 4' - 3" 3' - 6" PROPOSED 2ND FLOORW19 2' - 5" 2' - 6" 4' - 3" PROPOSED 2ND FLOORW20 2' - 5" 2' - 6" 4' - 3" PROPOSED 2ND FLOORW21 2' - 5" 2' - 6" 4' - 3" PROPOSED 2ND FLOOR
UPUPUP25' - 10 3/4"17' - 7 1/8"7' - 4 1/4"12' - 2 1/4"26' - 7 3/4"5' - 10"12' - 8 1/2"2' - 0 1/4"4' - 7"NEW CLOSETUNFINISHED BASEMENT STORAGEFAMILY ROOMSCSCD2D3D1D4ALL SMOKE AND CARBON-MONOXIDE DETECTORS MUST BE HARD-WIREDCARBON MONOXIDE DETECTORS[R315 PG. 68 AMENDED]• 1 IN EACH HABITAL STORY OF THE HOUSEAND WITHIN 10 FT. OF ALL BEDROOMS.COMBINATION PHOTOELECTRIC SENSITIVE SMOKE/CARBON MONOXIDE DETECTORS [R315.4 PG. 68 AMENDED]• MAY BE USED WHERE SMOKE DETECTORS ARE LOCATED PER R315,3HEAT DETECTORS • 1 IN EACH ATTACHED GARAGE, NEAR CENTER.PHOTOELECTRIC SENSITIVE SMOKE DETECTORS[R314 PG. 67 AMENDED]• 1 IN EACH SEPARATE BEDROOM• 1 OUTSIDE EACH SEPARATE BEDROOM• 1 NEAR BASE OF EACH STAIRWAY• 1 IN EVERY BASEMENT & WALK UP ATTIC• 1 FOR EVERY 1,000 SQ. FT.SCCSHLIFE SAFETY FIXTURES LEGENDBATH / LIGHT COMBO EXHAUST FANJOHNKARAVOLASCIVILNo. 38495COMMONWEALTHOFMASS ACHUS E T TS PR OFESSIONALENGINEER ScaleDateProject(978) 759-7799contact@soulveplus.comwww.soulveplus.com1/4" = 1'-0"1.1EXISTING ANDPROPOSEDBASEMENTHOME RENOVATION200 PARKER RD, OSTERVILLE-MA07/25/2024200BAS-OST1/4" = 1'-0"1EXISTING BASEMENT1/4" = 1'-0"2PROPOSED BASEMENT
DNUPUPDNEXISTINGBATHROOMEXISTINGLAUNDRYEXISTINGKITCHENEXISTINGOFFICE101sfEXISTINGDININGEXISTINGDINING8' - 11 1/4"8' - 4 1/2"6' - 4 1/2"EXISTINGDOOR TO REMAINEXISTING WALLS TO REMAINNEW WALLSWALL LEGENDBEDROOMBEDROOMBEDROOM10' - 0"20' - 0"20' - 0"10' - 0"JOHNKARAVOLASCIVILNo. 38495COMMONWEALTHOFMASS ACHUS E T TS PR OFESSIONALENGINEER ScaleDateProject(978) 759-7799contact@soulveplus.comwww.soulveplus.comAs indicated1.2EXISTING PLANS &PERSPECTIVESHOME RENOVATION200 PARKER RD, OSTERVILLE-MA07/25/2024200BAS-OST1/4" = 1'-0"1EXISTING 1ST FLOOR1/4" = 1'-0"2EXISTING 2ND FLOOR1" = 20'-0"3EXISTING SITE
DNUPUPDNLANDINGSTEPCHANGE THE ROOF A LITTLE BIT AND BIGGER DORMEREXISTING EXTERIOR WINDOW AND WALLS TO BE DEMOLISHEXISTING INTERIOR WALLS AND OPENINGS TO BE DEMOLISHEXISTING PARTS OF EXTERIOR WALL TO BE DEMOLISH FOR A NEW WINDOWEXISTING LANDING TO BE DEMOLISHEXISTING PARTS OF EXTERIOR WALL TO BE DEMOLISHEXISTING LAUNDRY CLOSET TO BE DEMOLISHDEMOLISH EXISTING WALLEXISTING WALLS TO REMAINNEW WALLSWALL LEGENDBEDROOMBEDROOMEXISTING WINDOW AND PARTS OF EXTERIOR WALL TO BE DEMOLISHEXISTING PARTS OF INTERIOR WALL TO BE DEMOLISHEXISTING DOORS AND INTERIOR WALL TO BE DEMOLISHEXISTING WINDOW AND PARTS OF EXTERIOR WALL TO BE DEMOLISHJOHNKARAVOLASCIVILNo. 38495COMMONWEALTHOFMASS ACHUS E T TS PR OFESSIONALENGINEER ScaleDateProject(978) 759-7799contact@soulveplus.comwww.soulveplus.com1/4" = 1'-0"1.3PROPOSEDDEMOLITION PLANS& PERSPECTIVESHOME RENOVATION200 PARKER RD, OSTERVILLE-MA07/25/2024200BAS-OST1/4" = 1'-0"1PROPOSED 1ST FLOOR DEMOLITION PLAN1/4" = 1'-0"2PROPOSED 2ND FLOOR DEMOLITION PLAN
DNUPUPREF.WasherDryerDNWasherDryer17' - 10"8' - 4 5/8"11' - 0 1/8"24' - 4 1/4"16' - 7 1/8"292 SFGARAGE79 SFLAUNDRY28 SFVESTIBULE338 SFKITCHEN140 SFDINING4' - 2 3/8"MIN.3' - 6"MIN.3' - 6"MIN.3' - 8"3' - 1 3/8"10' - 3"3' - 7 1/4"102 SFMUDROOMNEWBATHROOM6' - 10 1/8"12' - 0"3' - 7"1' - 0"LANDINGSTEPDISHWASHERMICROWAVE10' - 0"NEWOUTSIDE SHOWERCHANGE THE ROOF A LITTLE BIT AND BIGGER DORMER6' - 0"3' - 6"6' - 10 7/8"NEWGAS FIREPLACENEWOPENING19' - 4 1/2"EQEQ19' - 9 1/4"EQEQSCSCHD6D7W7W8W9W10W1D8D10W4W11D11D9W2D5W3W5W6D21NEWDECK9' - 3 3/4"6' - 11 5/8"5' - 10 1/8"EXISTINGOFFICENEWOPENINGEXISTING WALLS TO REMAINNEW WALLSWALL LEGENDBEDROOMBEDROOMNEWOFFICEHIS W.I.C.HERS W.I.C.13' - 6"9' - 10 3/4"2' - 8 5/8"GREEN LINE6' 0" CLG. HEIGHT2' - 6"6' - 0 1/4"8' - 6 1/4"WATERCLOSET3' - 6"3' - 0"3' - 0"5' - 6 5/8"16' - 2 5/8"NEWOFFICE DOORCYAN LINE6' 8" CLG. HEIGHTSCSCSCSCSCSSNEWDECKD20D12W12D13W13W14D14D15D17D18D19W15W16W17W18D16W19W20W2110' - 0"20' - 0"20' - 0"10' - 0"ALL SMOKE AND CARBON-MONOXIDE DETECTORS MUST BE HARD-WIREDCARBON MONOXIDE DETECTORS[R315 PG. 68 AMENDED]• 1 IN EACH HABITAL STORY OF THE HOUSEAND WITHIN 10 FT. OF ALL BEDROOMS.COMBINATION PHOTOELECTRIC SENSITIVE SMOKE/CARBON MONOXIDE DETECTORS [R315.4 PG. 68 AMENDED]• MAY BE USED WHERE SMOKE DETECTORS ARE LOCATED PER R315,3HEAT DETECTORS • 1 IN EACH ATTACHED GARAGE, NEAR CENTER.PHOTOELECTRIC SENSITIVE SMOKE DETECTORS[R314 PG. 67 AMENDED]• 1 IN EACH SEPARATE BEDROOM• 1 OUTSIDE EACH SEPARATE BEDROOM• 1 NEAR BASE OF EACH STAIRWAY• 1 IN EVERY BASEMENT & WALK UP ATTIC• 1 FOR EVERY 1,000 SQ. FT.SCCSHLIFE SAFETY FIXTURES LEGENDBATH / LIGHT COMBO EXHAUST FANJOHNKARAVOLASCIVILNo. 38495COMMONWEALTHOFMASS ACHUS E T TS PR OFESSIONALENGINEER ScaleDateProject(978) 759-7799contact@soulveplus.comwww.soulveplus.comAs indicated1.4PROPOSED PLANS& PERSPECTIVESHOME RENOVATION200 PARKER RD, OSTERVILLE-MA07/25/2024200BAS-OST1/4" = 1'-0"1PROPOSED 1ST FLOOR1/4" = 1'-0"2PROPOSED 2ND FLOOR1" = 20'-0"3SITE
PROPOSED 1STFLOOR0' -0"PROPOSED 2NDFLOOR8' -5 1/2"PROPOSED ATTIC16' -7 1/2"PROPOSED 1STFLOOR0' -0"PROPOSED 2NDFLOOR8' -5 1/2"PROPOSED 1STFLOOR0' -0"PROPOSED 2NDFLOOR8' -5 1/2"PROPOSED ATTIC16' -7 1/2"JOHNKARAVOLASCIVILNo. 38495COMMONWEALTHOFMASS ACHUS E T TS PR OFESSIONALENGINEER ScaleDateProject(978) 759-7799contact@soulveplus.comwww.soulveplus.com1/4" = 1'-0"1.5EXISTING EXTERIORELEVATIONSHOME RENOVATION200 PARKER RD, OSTERVILLE-MA07/25/2024200BAS-OST1/4" = 1'-0"1EXISTING FRONT ELEVATION1/4" = 1'-0"2EXISTING RIGHT SIDE ELEVATION1/4" = 1'-0"3EXISTING REAR SIDE ELEVATION1/4" = 1'-0"4EXISTING LEFT SIDE ELEVATION
PROPOSED 1STFLOOR0' -0"PROPOSED 2NDFLOOR8' -5 1/2"PROPOSED ATTIC16' -7 1/2"PROPOSED 1STFLOOR0' -0"PROPOSED 2NDFLOOR8' -5 1/2"PROPOSED 1STFLOOR0' -0"PROPOSED 2NDFLOOR8' -5 1/2"PROPOSED ATTIC16' -7 1/2"JOHNKARAVOLASCIVILNo. 38495COMMONWEALTHOFMASS ACHUS E T TS PR OFESSIONALENGINEER ScaleDateProject(978) 759-7799contact@soulveplus.comwww.soulveplus.com1/4" = 1'-0"1.6PROPOSEDEXTERIORELEVATIONSHOME RENOVATION200 PARKER RD, OSTERVILLE-MA07/25/2024200BAS-OST1/4" = 1'-0"1PROPOSED FRONT ELEVATION1/4" = 1'-0"2PROPOSED RIGHT SIDE ELEVATION1/4" = 1'-0"3PROPOSED REAR SIDE ELEVATION1/4" = 1'-0"4PROPOSED LEFT SIDE ELEVATION
OSTERVILLE, MA 02655
115022
WIANNO CLUB
P O BOX 249
Property ID:
WESTWOOD, MA 02090
116037
RYAN, FRANCIS J JR & KATRINA
387 FAR REACH ROAD
Property ID:
168 PARKER ROAD
OSTERVILLE, MA 02655
116038
MEADS, ANNE E & CHARLES E TRS
CE MEADS TRUST & AE MEADS TRUST
Property ID:
101 FEDERAL STREET 14TH FLOOR
BOSTON, MA 02210
116039
KOOP, BRYAN J
C/O RINET COMPANY
Property ID:
190 PARKER ROAD
OSTERVILLE, MA 02655
116040
PAWLOSKI, MILES J & KATHLEEN H TRS
PAWLOSKI FAMILY TRUST
Property ID:
OSTERVILLE, MA 02655
116041
BARKER, DENISE & SCOTT
200 PARKER ROAD
Property ID:
LONG VALLEY, NJ 07853
116042
BALLOTTI, GEOFFREY A & LESLIE A
462 WEST MILL ROAD
Property ID:
144 OLD WESTFORD RD
CHELMSFORD, MA 01842
116043
CAROTA, MARK C & JOANNE M TRS
MARK CAROTA LIVING TRUST
Property ID:
OSTERVILLE, MA 02655
116044
SEIFERT, KEVIN J
97 FIRST AVENUE
Property ID:
OSTERVILLE, MA 02655
116045
REILLY, SEAN M & KARA
71 FIRST AVENUE
Property ID:
7 LEE ROAD
CHESTNUT HILL, MA 02467
116046
KINLAN, JAMES & CAROL TRS
JAMES E KINLAN FAMILY TRUST
Property ID:
55 FIRST AVENUE
OSTERVILLE, MA 02655
116047
LEAHY, CHRISTOPHER D TR
CHRISTOPHER D LEAHY 2023 TRUST
Property ID:
OSTERVILLE, MA 02655
116048
COLEMAN, NAOMI
47 FIRST AVE
Property ID:
41 FIRST AVENUE
OSTERVILLE, MA 02655
116049
WYATT, SARAH A TR
SARAH A WYATT TRUST
Property ID:
PROVIDENCE, RI 02903
116057
MCCARTHY, LAWRENCE P & SHARON F
100 EXCHANGE STREET UNIT 801
Property ID:
SHARON, MA 02067
116058
BARRY, MICHELLE & SONIA, LAURINA A
17 CAPE CLUB DRIVE
Property ID:
114 FIRST AVENUE
OSTERVILLE, MA 02655
116059
GERMANI, MARK P TR
GERMANI REALTY TRUST
Property ID:
WELLESLEY, MA 02482
116060
FULHAM, TIMOTHY W & OLNEY, LISE M
15 WINDSOR ROAD
Property ID:
234 PARKER ROAD
OSTERVILLE, MA 02655-0574
11606100A
THOMANN, ALBERT H & MARIA I TRS
THOMANN TRUST
Property ID:
234 PARKER ROAD
UNIT 1-A
11606100B
THOMANN, ALBERT H & MARIA A TRS
THOMANN TRUST
OSTERVILLE, MA 02655
Property ID:
WEST HARTFORD, CT 06119
11606100C
DUGGAN, JEANNE S
302 CUMBERLAND RD
Property ID:
COLUMBUS, OH 43214
11606100D
PARMATER, JOHN
158 WEST NORTH BROADWAY STREET
Property ID:
OSTERVILLE, MA 02655
11606100E
PARMATER, SUSAN
234 PARKER ROAD
Property ID:
WALTHAM, MA 02453
11606100F
POWERS, GERALDINE
23 ROBBINS STREET UNIT 31
Property ID:
OSTERVILLE, MA 02655
11606100G
PEDERSEN, CAROL A
P O BOX 163
Property ID:
WELLESLEY, MA 02482
11606100H
ALVARADO, ALEJANDRO & SARAH
6 JUNIPER ROAD
Property ID:
35 DEXTER ROAD
FOXBOROUGH, MA 02035
11606100I
MORRISSEY, JOAN M TR
JOAN M MORRISSEY FAMILY TRUST
Property ID:
35 DEXTER ROAD
FOXBORO, MA 02035
11606100J
MORRISSEY, JOAN M TR
JOAN M MORRISSEY FAMILY TRUST
Property ID:
OSTERVILLE, MA 02655
116062
CUSACK, JOSEPH W & ALICE M
34 SECOND AVE
Property ID:
243 PARKER ROAD
116077
JACKSON, BRIAN R & COLLEEN S TRS
JACKSON FAMILY REVOCABLE TRUST
OSTERVILLE, MA 02655
Property ID:
233 PARKER ROAD
OSTERVILLE, MA 02655
116078
JENKINS, SUSAN F TR
233 PARKER ROAD REALTY TRUST
Property ID:
1512 OCEAN DUNES CIRCLE
JUPITER, FL 33477
116079
PARKER ROAD LLC
C/O ROSS, WILLIAM A, TRS
Property ID:
207 PARKER ROAD
OSTERVILLE, MA 02655
116080
CURRIE, GERARD RICHARD & CURRIE,
GERARD RICHARD CURRIE TRUST
Property ID:
WELLESLEY, MA 02481
116081
FULHAM, TIMOTHY W & OLNEY, LISE M
15 WINDSOR ROAD
Property ID:
53 FARM STREET
DOVER, MA 02030
116082
LUCCHESI, MAURO & DIANE V TRS
LUCCHESI REALTY TRUST
Property ID:
LINCOLN, MA 01773
116083
BOMBARA, MARK A & ROSAMARIA P
44L INDIAN CAMP LANE
Property ID:
101 FEDERAL ST 14TH FLOOR
BOSTON, MA 02110
116084
KOOP, SUSAN K
C/O RINET COMPANY-KYLE PIROLLI
Property ID:
NEWTOWN, PA 18940
116085
MCDERMOTT, WILLIAM J & KATHLEEN
35 S. CHANCELLOR STREET
Property ID:
NEWTOWN, PA 18940
116122
MCDERMOTT, WILLIAM J & KATHLEEN
35 S. CHANCELLOR STREET
Property ID:
MILFORD, MA 01757
116131
DALLAMORA, RACHEL D & MATTHEW
9 WESTCHESTER DRIVE
Property ID: