HomeMy WebLinkAboutAP-2024-033 6M Development - ElevationsW04W04W04W04W04W04W04W04 W03W03W03W03W03W03W03W03W03W03W03W03 W04W04W04W04W04W04W04W04 31'4'6 / 12 6 / 12 W04W04W04W04W04W04W04W04 W03W03W03W03W03W03W03W03W03W03W03W03 W04W04W04W04W04W04W04W04 Exterior Elevation Front W02W02W02W02 W05W05 W03W03 W01W01W02W02W02W02W02W02 4'6 / 12 6 / 12 W02W02W02W02 W05W05 W03W03 W01W01W02W02W02W02W02W02 Exterior Elevation Back REVISION TABLEDATEREVISED BYDESCRIPTIONMARTIN DESIGNSBELLINGHAM - MAMARTINDESIGNSINC@GMAIL.COMCLIENT INFORMATION:WILLIAM CAULDER1045 MAIN STCOTUIT - MASCALE: 3/8" = 1'-0" DATE: 8/27/2024 DISCLAIMER: THIS DRAWING IS FOR REPRESENTATION PURPOSES ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND TO CONFORM WITH LOCAL AND STATE BUILDING CODES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THE SAFETY AND PROPER BUILDING OF THE STRUCTURE REPRESENTED. THESE DRAWINGS HAVE BEEN REVIEWED BY A PROFESSIONAL ENGINEER IN THE STATE OF MASSACHUSETTS. ALL NEW CONSTRUCTION SHALL COMPLY WITH THE MASSACHUSETTS STATE BUILDING CODE 9TH EDITION CMR.COPYRIGHT: THESE DRAWINGS ARE EXCLUSIVE PROPERTY OF MARTIN DESIGNS. REPRODUCTION OF THESE PLANS IS STRICTLY PROHIBITED. PROPOSED BARN ELEVATIONS A-1 GENERAL NOTES:GENERAL NOTES: 1 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND LOCAL BUILDING CODES AND REQUIREMENTS. 2 ALL NEW CONSTRUCTION SHALL COMPLY WITH THE MASSACHUSETTS STATE BUILDING CODE 9TH EDITION CMR. 3 THE GENERAL CONTRACTOR SHALL REVIEW AND NOTIFY MARTIN DESIGNS OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK. 4 THE GENERAL CONTRACTOR SHALL LEAVE THE PROJECT SITE CLEAR AT ALL TIMES AND REMOVE ALL DEBRIS. 5 THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, PATCHING, CHASING, AND REPAIRING REQUIRED TO PERFORM THE WORK. 6 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WORK OF ALL TRADES. 7 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL ALL MATERIALS AND EQUIPMENT AS PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. 8 DIMENSIONS ARE TO CENTER LINES, TO FACE OF FINISHED SURFACE, OR EXISTING BUILDING GRID LINES. 9 THESE DRAWINGS ARE NOT TO BE SCALED FOR DIMENSIONS. 10 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL INSTALLATIONS, CONDITIONS, MATERIALS AND FINISHES WITH THE PROPOSED SCOPE OF WORK. 11 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION. 12 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING, PAYING, AND SCHEDULING INSPECTIONS AND PULLING PERMITS. 13 ALL PENETRATIONS SHALL BE SEALED TIGHT WITH UL-LISTED FIRESTOPPING. 14 ALL DATA OUTLETS MUST BE ON A DEDICATED, ISOLATED CIRCUIT. FOR PROPER SCALE; THESE DRAWINGS SHOULD BE PRINTED ON ARCH D PAPER SIZE (24"x36") DESIGN CRITERIA:DESIGN CRITERIA: 40 PSF LIVING AREA LIVE LOADS 30 PSF SLEEPING AREA LIVE LOADS 20 PSF UNINHABITABLE ATTIC LIVE LOADS 15 PSF ROOF DEAD LOADS 30 PSF ROOF SNOW LOADS 60 PSF BALCONIES AND DECKS LIVE LOADS WIND SPEED: 140 mph - Exposure B FROST WALL DEPTH: 4'-0" P.E. STAMP CUSTOM ORDERCUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER 4'4'3 / 1 2 6 / 1 2 6 / 12 3 / 12 10" OVERHANGS VERTICAL SIDING 4' FROSTWALL CUSTOM ORDERCUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER Exterior Elevation Left W03W03W03W03 W03W03 4'3 / 1 2 6 / 1 2 6 / 12 3 / 12 W03W03W03W03 W03W03 Exterior Elevation Right REVISION TABLEDATEREVISED BYDESCRIPTIONMARTIN DESIGNSBELLINGHAM - MAMARTINDESIGNSINC@GMAIL.COMCLIENT INFORMATION:WILLIAM CAULDER1045 MAIN STCOTUIT - MASCALE: 3/8" = 1'-0" DATE: 8/27/2024 DISCLAIMER: THIS DRAWING IS FOR REPRESENTATION PURPOSES ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND TO CONFORM WITH LOCAL AND STATE BUILDING CODES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THE SAFETY AND PROPER BUILDING OF THE STRUCTURE REPRESENTED. THESE DRAWINGS HAVE BEEN REVIEWED BY A PROFESSIONAL ENGINEER IN THE STATE OF MASSACHUSETTS. ALL NEW CONSTRUCTION SHALL COMPLY WITH THE MASSACHUSETTS STATE BUILDING CODE 9TH EDITION CMR.COPYRIGHT: THESE DRAWINGS ARE EXCLUSIVE PROPERTY OF MARTIN DESIGNS. REPRODUCTION OF THESE PLANS IS STRICTLY PROHIBITED. A-2 FRAMING NOTES:FRAMING NOTES: 1 ALL FRAMING WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE MASSACHUSETTS RESIDENTIAL BUILDING CODE 9TH EDITION CMR. 2 MARTIN DESIGNS MAKES NO CLAIMS TOWARDS EXISTING CONDITIONS. 3 GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY BRACING BEFORE AND DURING FRAMING. 4 ALL SILL PLATES, WALL BASE AT GARAGE, BASEMENT, DECK & PORCH FRAMING SHALL BE PRESSURE TREATED. 5 ALL FRAMING LUMBER, BEAMS, JOISTS, RAFTERS, HEADERS, PLATES AND SILL SHALL BE SPRUCE PINE FIR #2 OR BETTER. 6 ALL JOIST AND BEAM HANGERS SHALL BE SIMPSON GALVANIZED. 7 ALL WALL SHEATHING SHALL BE 1/2" CDX PLYWOOD. 8 PLYWOOD SUBFLOORS SHALL BE TONGUE AND GROOVE, 3/4" THICK, A/C. 9 BLOCK ALL JOIST BAYS WITH 2x10 SYP PT. 10 USE GALVANIZED SIMPSON HURRICANE CLIPS ON EVERY JOIST. 11 USE GALVANIZED SIMPSON POST CAP ON EVERY POST. 12 ALL DECK BEAMS, POSTS, AND EXPOSED LUMBER SHALL BE PRESSURE TREATED. 13 ALL NAILS, BOLTS AND HARDWARE SHALL BE PRESSURE TREATED. 14 36" MIN. RAILING AROUND DECK AND STAIRS. 15 BLOCK IN BETWEEN EVERY JOIST BAYS DEMOLITION NOTES:DEMOLITION NOTES: 1 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND LOCAL BUILDING CODES AND REQUIREMENTS. 2 GENERAL CONTRACTOR SHALL ACCEPT FULL RESPONSIBILITY FOR THE STABILITY AND STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURES WITHIN AND ADJACENT TO THE WORKS. 3 THE GENERAL CONTRACTOR SHALL PROVIDE ANY NECESSARY WALL BRACING PRIOR TO REMOVING ANY WALLS. 4 THE GENERAL CONTRACTOR SHALL MAINTAIN THE WORK SITE CLEAN AND DEBRIS FREE AT ALL TIMES. 5 THE GENERAL CONTRACTOR SHALL REMOVE ANY DEBRIS FROM THE CONSTRUCTION SITE. 6 THE GENERAL CONTRACTOR TO MAKE SURE THAT ALL EXTERIOR OPENINGS ARE PROPERLY COVERED FROM THE WEATHER. INTERIOR OF THE HOUSE SHALL NOT BE EXPOSED TO THE WEATHER. 7 ALL GAS/WATER/SEWER/ELECTRIC LINES SHALL BE REMOVED OUT OF THE WAY BEFORE DEMOLITION BEGINS. FOR PROPER SCALE; THESE DRAWINGS SHOULD BE PRINTED ON ARCH D PAPER SIZE (24"x36") ROOF NOTES:ROOF NOTES:1 30 YEAR ASPHALT SHINGLES OR EQUAL2ALL ROOF SHEATHING SHALL BE 5/8" TONGUE AND GROOVE CDX PLYWOOD. 3 3'-0" WIDE ICE & WATER SHIELD AT ALL ROOF/WALL JUNCTIONS. 4 GENERAL CONTRACTOR TO PROVIDE FLASHING PER MANUFACTURER'SINSTALLATION REQUIREMENTS AT ALL ROOF/WALL JUNCTIONS.5 CONTINUOUS ROOF VENT TYPICAL. 6 ALUMINUM DRIP EDGE. 7 ALUMINUM GUTTERS & DOWNSPOUTS.8 1x8 FASCIA & SOFFIT WITH 2" CONTINUOUS VENT. 2x SUB-FASCIA. 1X2 TRIM9USE SIMPSON HURRICANE CLIPS AS REQUIRED BY MASSACHUSETTS STATEBUILDING CODE.10 GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING ANDSHORING TO AVOID EXCESSIVE STRESSES AND HOLD STRUCTURAL ELEMENTS INPLACE DURING CONSTRUCTION.11 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGSARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVECROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGSPROTECTED AGAINST THE ENTRANCE OF RAIN AND/OR SNOW. 12 VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF 1/16 INCH MINIMUMAND 1/4 INCH SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE CLOTHSCREENING, HARDWARE CLOTH OR SIMILAR MATERIAL WITH OPENINGS HAVING ALEAST DIMENSION OF 1/16 INCH MINIMUM AND 1/4 INCH MAXIMUM. PROPOSED BARN ELEVATIONS P.E. STAMP CUSTOM ORDERW01W01 60806080308090809080 W04W04W04W043080W04W04W04W04 26682668 3068W02W02 W02W02 W02W02 3080UP UP 3 PLY 2x10 HEADER 3 PLY 2x10 HEADER SOLE PLATE DOUBLE TOP PLATECRIPPLE STUDS ROUGH OPENING TYP. TWO 2x6 JACK STUDS & ONE KING STUD CUT & REMOVED AFTER WALL IS ERECTED TWO 2x6 JACK STUDS & ONE KING STUD 2x6 1/3 SPAN BLOCKING 2x6 KD STUDS @ 16" O.C. TYPICAL WALL FRAMING DETAIL NOT TO SCALE 1ST FLOOR WALL ROUGH HEIGHT2ND FLOOR WALL ROUGH HEIGHT6x8 Post 6x8 Post 6x8 Post SDCO HD HD 3'9'2'9'3' 26'26' 52'28'38'10'38'26'26' 52'13'-2"8'10'8'-6"9'8'-6"10'3'-2" 12'-6" 4'-6"3'-6"8'5'6'14'-10"18'24'2' 5'8'8'5'5'5'5'15'6'5'10'14'13'10'-2 3/4"13' 3'-10 1/4"5'-11 1/2" 6'-8 3/4"3'-3"6'-6" 25'-0" X 37'-0" 925 SQ FT 25'-6" X 14'-4" 363 SQ FT 19'-1" X 12'-8" 225 SQ FT 6'-1" X 12'-6" 61 SQ FT 5'-7" X 4'-10" 27 SQ FT 25'-0" X 9'-5" 236 SQ FT 2-CAR GARAGE BATH KITCHEN FIREPLACE2x4 BEARING WALL STORAGE EQUIPMENT 26' x 10' COVERED PORCH 260 SQ-FT FAN LINE OF WALL ABOVE CLOSET GREAT ROOM 9'-0" CEILING HEIGHT 9'-0" CEILING HEIGHT WINDOW SCHEDULE LINE OF WALL ABOVE EV CHARGING PORT 15 Risers @ 8" 14 Treads @ 10" FINISHED 4" LALLY COLUMN w/ 6"x8" SPRINGFIELD PLATES ON 24"x24"x24" CONCRETE FOOTINGS. 4" LALLY COLUMN w/ 6"x8" SPRINGFIELD PLATES ON 24"x24"x24" CONCRETE FOOTINGS.36" min. RailingsSMOKE DETECTORCARBON MONOXIDE DETECTORHEAT DETECTORNOTES:-ALL SMOKE DETECTORS SHALL BEPHOTOELECTRIC.-ALL CARBON MONOXIDE DETECTORSSHALL BE KIDDE PI2010.-ALL HEAT DETECTORS SHALL BE KIDDEFIREX HARDWIRED INTER-CONNECTABLE.SMOKE DETECTORS & CARBON MONOXIDE DETECTORS SMOKE DETECTORS SHALL BE INSTALLED IN THE FOLLOWINGLOCATIONS: IN THE IMMEDIATE VICINITY OF BEDROOMS, ALLBEDROOMS ON EACH FLOOR INCLUDING BASEMENTS ANDATTICS.PHOTOELECTRIC SMOKE DETECTORSANY SMOKE DETECTOR LOCATED WITHIN 20 FEET OF A KITCHENOR WITHIN 20 FEET OF A BATHROOM CONTAINING A TUB OR ASHOWER SHALL BE PHOTOELECTRIC TYPE SMOKE DETECTORS.INSULATION NOTES:USE 2" RIGID INSULATION UNDER FOUNDATIONSLABUSE R-30 ON 2x6 EXTERIOR WALLS (SPRAY FOAM )USE R-30 ON GARAGE CEILINGUSE R-60 ON ROOF RAFTERS(SPRAY FOAM) S-1S-1 DOOR AND WINDOW NOTES:EVERY BEDROOM SHALL BE PROVIDED WITH AN EGRESS WINDOWWITH FINISH SILL HEIGHT NOT GREATER THAN 44" ABOVE THEFINISH FLOOR HEIGHT AND SHALL HAVE A MINIMUM OPENABLEAREA OF 5.7 SQ. FT. EGRESS WINDOWS SHALL NOT HAVE ANOPENABLE AREA LESS THAN 20" WIDE OR 24" HIGH. MIN. U-VALUEOF 0.30. G.C. SHALL PROVIDE ALL WINDOW SPECS TO THEBUILDING DEPARTMENT.ALL WALK-THRU DOORS SHALL BE SOLID COREINTERIOR DOORS SHALL BE PAINTED. ENTRY DOOR TO BEDEFINED BY HOME OWNER PRIOR ORDERINGDOORS BETWEEN GARAGE AND LIVING AREA SHALL BE 1-3/4"TIGHT FITTING SOLID CORE DOORS WITH A RATING OF 60MINUTES. DOOR SHALL BE SELF CLOSINGEXTERIOR EXIT DOORS WILL BE 36" MIN. NET CLEAR DOORWAYSHALL BE 32" MIN. DOOR SHALL BE OPENABLE FROM INSIDEWITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OREFFORT. GLAZING IN DOORS SHALL BE DUAL PANE SAFETY GLASSWITH MIN. U-VALUE OF 0.30 GARAGE DOORS TO BE SECTIONAL, OVERHEAD DOORS 1st Floor DN CUSTOM ORDERCUSTOM ORDERW05W05 W03W03 W03W03W03W03W03W03W03W03W03W03W03W03 W03W03 W03W03 W03W03266826685068 266826682868 2868 2668 MAXIMUM ALLOWABLE SPAN CHART FOR SPRUCE-PINE-FIR #2 O.C. SPACING (INCHES) MEMBER SIZE FLOOR JOISTS 40psf LL / 10 psf DL / L/360 DEFLECTION CEILING JOISTS 20psf LL / 10 psf DL / L/240 DEFLECTION UNINHABITABLE ROOF RAFTERS 30psf GSL / 20 psf DL / L/180 DEFLECTION NOTES: LL = LIVE LOAD / DL = DEAD LOAD / GSL = GROUND SNOW LOAD THE ABOVE FLOOR JOIST TABLE IS BASED ON THE IRC 2018 TABLE R502.3.1(2) THE ABOVE CEILING JOIST TABLE IS BASED ON THE IRC 2018 TABLE R802.5.1(2) THE ABOVE ROOF RAFTER TABLE IS BASED ON THE IRC 2018 TABLE R802.4.1(3) FOUNDATION WALL FOOTING DETAIL NOT TO SCALE 10" FOUNDATION WALL 24"x10" FOUNDATION FOOTING w/ KEY STRIP FOOTING DETAIL NOT TO SCALE 24"x24" STRIP FOOTING LCE4 LCE4 POST CAP DETAIL NOT TO SCALE SIMPSON HANGER CONNECTION DETAIL NOT TO SCALE LUS SIMPSON HANGER SIMPSON HURRICANE CONNECTOR DETAIL NOT TO SCALE SIMPSON HURRICANE TIE H2.5A 2x RAFTER DOUBLE 2X TOP PLATE SIMPSON ABA66z DETAIL NOT TO SCALE CO SD SD SD 28'52'10'-3"7'-6"10'-3"12'12'16'-6" 13'10' 12'-6" 8'4'5'-6"8'-6"8'-6"5'-6"3'6'-8"11'-10"10'-3"16'-4"6'-8"5'-3"7'-7"6'20'20'6' 8'-5 1/4"7'-6"12'-6"28'15'-9" X 27'-0" 454 SQ FT 11'-10" X 9'-7" 114 SQ FT 7'-8" X 7'-8" 58 SQ FT 3'-0" X 6'-8" 20 SQ FT 9'-8" X 7'-9" 63 SQ FT 6'-3" X 3'-6" 22 SQ FT 7'-9" X 7'-2" 55 SQ FT27'-2" X 5'-9" 115 SQ FT 11'-6" X 11'-4" 130 SQ FT 12'-8" X 11'-4" 143 SQ FT 7'-8" X 3'-4" 25 SQ FT 11'-10" X 9'-7" 120 SQ FT LIVING AREA BATH OPEN TO BELOW 36" RAILINGSBATH BATH HALL BEDROOM 2 PRIMARY BEDROOM SHOWER CLOSET FITNESS ROOM OFFICE FINISHED SQ-FT 1ST FLOOR = 681 SQ-FT 2ND FLOOR = 908 SQ-FT TOTAL = 1,589 SQ-FT CLOSET FAN FAN8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT FAN EGRESS EGRESS ATTIC ACCESS 24"x36" S-1S-1 2x6 BOTTOM CHORDS 12 61262x6 T O P C H O R D S 2x6 TOP CHORDSSTORAGE 2nd Floor FOUNDATION WALL FOOTING DETAIL NOT TO SCALE 10" FOUNDATION WALL 24"x10" FOUNDATION FOOTING w/ KEY STRIP FOOTING DETAIL NOT TO SCALE 24"x24" STRIP FOOTING 26'26' 52'48'26'26' 52'28'38'10'10'2'-9"9'-6"1'-6"9'-6"2'-9"13'-2"10"2'10"2'10" 2' 10" 2' 16'-6"9'-6" 24" x 24" STRIP FOOTING. SEE DETAIL CONCRETE SLAB SURFACE TO SLOPE 2% OR 1/4" PER FOOT TO PROVIDE ADEQUATE DRAINAGE FIELD COORDINATE T.O.C. DROP PER GARAGE SLAB ELEVATION NEW 4" CONCRETE SLAB ON 6 MIL. VAPOR BARRIER 6"x6"x10/10 WELDED WIRE MESH & 4" MIN. COMPACTED GRAVEL 2" RIGID INSULATION NEW 4" CONCRETE SLAB ON 6 MIL. VAPOR BARRIER 6"x6"x10/10 WELDED WIRE MESH & 4" MIN. COMPACTED GRAVEL 2" RIGID INSULATION NEW 4" CONCRETE SLAB ON 6 MIL. VAPOR BARRIER 6"x6"x10/10 WELDED WIRE MESH & 4" MIN. COMPACTED GRAVEL 2" RIGID INSULATION 24" WIDE x 10" CONCRETE FOOTINGS (Typ.) 48" FROSTWALL BELOW GRADE 5/8" DIA. 1'-0" APART HOLD DOWNS ON ALL CORNERS (Typ.) 5/8" DIA. 1'-0" APART HOLD DOWNS ON ALL CORNERS (Typ.) 5/8" DIA. 1'-0" APART HOLD DOWNS ON ALL CORNERS (Typ.) SLAB ON GRADE SLAB ON GRADE SLAB ON GRADE 48" FROSTWALL BELOW GRADE 48" FROSTWALL BELOW GRADE48" FROSTWALL BELOW GRADE 48" FROSTWALL BELOW GRADE 24" x 24" STRIP FOOTING. SEE DETAIL Foundation CONCRETE FOUNDATION CONCRETE FOOTING FOUNDATION WALL FOOTING DETAIL NOT TO SCALE 10" FOUNDATION WALL 24"x10" FOUNDATION FOOTING w/ KEY 24"24"STRIP FOOTING DETAIL NOT TO SCALE 24"x24" STRIP FOOTING DOUBLE #4 REBARS GRADE 6048"2" RIGID INSULATION 4" CONCRETE SLAB 6x6x10 WIRE MESH Garage Slab Detail Not To Scale 7/16" ZIP SHEATHING/SIDING 1" EXPANSION JOINT 2x6 TREATED MUDSILL CAST-IN-PLACE 5/8" ANCHOR BOLT AND 3" X 3" X 1/4" PLATE WASHER AT 24" O.C. 2x6 STUD WALL SILL SEALER 10" CONCRETE FOUNDATION 10" x 24" CONCRETE FOOTING 4" GRAVEL VAPOR BARRIER 2" RIGID INSULATION (2) #4 REBARS KEYWAY 48" FROSTWALL BELOW GRADE 4" FLEXIBLE HDPE (high-density polyethylene) DRAINAGE SYSTEM 4" CONCRETE SLAB 6x6x10 WIRE MESH Slab on Grade Foundation Detail Not To Scale 7/16" ZIP SHEATHING/SIDING 2" RIGID INSULATION (4) 2x4 PT SILL PLATE 18" LONG CAST-IN-PLACE 5/8" ANCHOR BOLT AND 3" X 3" X 1/4" PLATE WASHER AT 24" O.C. SILL SEALER 10" CONCRETE FOUNDATION 10" x 24" CONCRETE FOOTING 4" GRAVEL VAPOR BARRIER 2" RIGID INSULATION 2" RIGID INSULATION (2) #4 REBARS KEYWAY 48" FROSTWALL BELOW GRADE 4" FLEXIBLE HDPE (high-density polyethylene) DRAINAGE SYSTEM SOIL GAS RETARDER MEMBRANE R-30 INSULATION 2x6 STUD WALL 2x6 PT SILL PLATE 24" x 24" STRIP FOOTING. SEE DETAIL CONCRETE SLAB SURFACE TO SLOPE 2% OR 1/4" PER FOOT TO PROVIDE ADEQUATE DRAINAGE FIELD COORDINATE T.O.C. DROP PER GARAGE SLAB ELEVATION NEW 4" CONCRETE SLAB ON 6 MIL. VAPOR BARRIER 6"x6"x10/10 WELDED WIRE MESH & 4" MIN. COMPACTED GRAVEL 2" RIGID INSULATION NEW 4" CONCRETE SLAB ON 6 MIL. VAPOR BARRIER 6"x6"x10/10 WELDED WIRE MESH & 4" MIN. COMPACTED GRAVEL 2" RIGID INSULATION NEW 4" CONCRETE SLAB ON 6 MIL. VAPOR BARRIER 6"x6"x10/10 WELDED WIRE MESH & 4" MIN. COMPACTED GRAVEL 2" RIGID INSULATION 24" WIDE x 10" CONCRETE FOOTINGS (Typ.) 48" FROSTWALL BELOW GRADE 5/8" DIA. 1'-0" APART HOLD DOWNS ON ALL CORNERS (Typ.) 5/8" DIA. 1'-0" APART HOLD DOWNS ON ALL CORNERS (Typ.) 5/8" DIA. 1'-0" APART HOLD DOWNS ON ALL CORNERS (Typ.) SLAB ON GRADE SLAB ON GRADE SLAB ON GRADE 48" FROSTWALL BELOW GRADE 48" FROSTWALL BELOW GRADE48" FROSTWALL BELOW GRADE 48" FROSTWALL BELOW GRADE 24" x 24" STRIP FOOTING. SEE DETAIL 3 PLY 2x10 HEADER 3 PLY 2x10 HEADER SOLE PLATE DOUBLE TOP PLATE CRIPPLE STUDS ROUGH OPENING TYP. TWO 2x6 JACK STUDS & ONE KING STUD CUT & REMOVED AFTER WALL IS ERECTED TWO 2x6 JACK STUDS & ONE KING STUD 2x6 1/3 SPAN BLOCKING 2x6 KD STUDS @ 16" O.C. TYPICAL WALL FRAMING DETAIL NOT TO SCALE 1ST FLOOR WALL ROUGH HEIGHT2ND FLOOR WALL ROUGH HEIGHTHD CO SD FIREPLACE2x4 BEARING WALL 26' x 10' COVERED PORCH 260 SQ-FT FAN LINE OF WALL ABOVE 9'-0" CEILING HEIGHT 9'-0" CEILING HEIGHT LINE OF WALL ABOVE EV CHARGING PORT 15 Risers @ 8" 14 Treads @ 10" FINISHED 4" LALLY COLUMN w/ 6"x8" SPRINGFIELD PLATES ON 24"x24"x24" CONCRETE FOOTINGS. 4" LALLY COLUMN w/ 6"x8" SPRINGFIELD PLATES ON 24"x24"x24" CONCRETE FOOTINGS.36" min. RailingsSMOKE DETECTOR CARBON MONOXIDE DETECTOR HEAT DETECTOR NOTES: -ALL SMOKE DETECTORS SHALL BE PHOTOELECTRIC. -ALL CARBON MONOXIDE DETECTORS SHALL BE KIDDE PI2010. -ALL HEAT DETECTORS SHALL BE KIDDE FIREX HARDWIRED INTER-CONNECTABLE. SMOKE DETECTORS & CARBON MONOXIDE DETECTORS SMOKE DETECTORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: IN THE IMMEDIATE VICINITY OF BEDROOMS, ALL BEDROOMS ON EACH FLOOR INCLUDING BASEMENTS AND ATTICS. PHOTOELECTRIC SMOKE DETECTORS ANY SMOKE DETECTOR LOCATED WITHIN 20 FEET OF A KITCHEN OR WITHIN 20 FEET OF A BATHROOM CONTAINING A TUB OR A SHOWER SHALL BE PHOTOELECTRIC TYPE SMOKE DETECTORS. INSULATION NOTES: USE 2" RIGID INSULATION UNDER FOUNDATION SLAB USE R-30 ON 2x6 EXTERIOR WALLS (SPRAY FOAM ) USE R-30 ON GARAGE CEILING USE R-60 ON ROOF RAFTERS(SPRAY FOAM) DOOR AND WINDOW NOTES: EVERY BEDROOM SHALL BE PROVIDED WITH AN EGRESS WINDOW WITH FINISH SILL HEIGHT NOT GREATER THAN 44" ABOVE THE FINISH FLOOR HEIGHT AND SHALL HAVE A MINIMUM OPENABLE AREA OF 5.7 SQ. FT. EGRESS WINDOWS SHALL NOT HAVE AN OPENABLE AREA LESS THAN 20" WIDE OR 24" HIGH. MIN. U-VALUE OF 0.30. G.C. SHALL PROVIDE ALL WINDOW SPECS TO THE BUILDING DEPARTMENT. ALL WALK-THRU DOORS SHALL BE SOLID CORE INTERIOR DOORS SHALL BE PAINTED. ENTRY DOOR TO BE DEFINED BY HOME OWNER PRIOR ORDERING DOORS BETWEEN GARAGE AND LIVING AREA SHALL BE 1-3/4" TIGHT FITTING SOLID CORE DOORS WITH A RATING OF 60 MINUTES. DOOR SHALL BE SELF CLOSING EXTERIOR EXIT DOORS WILL BE 36" MIN. NET CLEAR DOORWAY SHALL BE 32" MIN. DOOR SHALL BE OPENABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. GLAZING IN DOORS SHALL BE DUAL PANE SAFETY GLASS WITH MIN. U-VALUE OF 0.30 GARAGE DOORS TO BE SECTIONAL, OVERHEAD DOORS REVISION TABLEDATEREVISED BYDESCRIPTIONMARTIN DESIGNSBELLINGHAM - MAMARTINDESIGNSINC@GMAIL.COMCLIENT INFORMATION:WILLIAM CAULDER1045 MAIN STCOTUIT - MASCALE: 3/8" = 1'-0" DATE: 8/27/2024 DISCLAIMER: THIS DRAWING IS FOR REPRESENTATION PURPOSES ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND TO CONFORM WITH LOCAL AND STATE BUILDING CODES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THE SAFETY AND PROPER BUILDING OF THE STRUCTURE REPRESENTED. THESE DRAWINGS HAVE BEEN REVIEWED BY A PROFESSIONAL ENGINEER IN THE STATE OF MASSACHUSETTS. ALL NEW CONSTRUCTION SHALL COMPLY WITH THE MASSACHUSETTS STATE BUILDING CODE 9TH EDITION CMR.COPYRIGHT: THESE DRAWINGS ARE EXCLUSIVE PROPERTY OF MARTIN DESIGNS. REPRODUCTION OF THESE PLANS IS STRICTLY PROHIBITED. A-3 DEMOLITION NOTES:DEMOLITION NOTES: 1IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND LOCAL BUILDING CODES AND REQUIREMENTS. 2GENERAL CONTRACTOR SHALL ACCEPT FULL RESPONSIBILITY FOR THE STABILITY AND STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURES WITHIN AND ADJACENT TO THE WORKS. 3THE GENERAL CONTRACTOR SHALL PROVIDE ANY NECESSARY WALL BRACING PRIOR TO REMOVING ANY WALLS. 4THE GENERAL CONTRACTOR SHALL MAINTAIN THE WORK SITE CLEAN AND DEBRIS FREE AT ALL TIMES. 5THE GENERAL CONTRACTOR SHALL REMOVE ANY DEBRIS FROM THE CONSTRUCTION SITE. 6THE GENERAL CONTRACTOR TO MAKE SURE THAT ALL EXTERIOR OPENINGS ARE PROPERLY COVERED FROM THE WEATHER. INTERIOR OF THE HOUSE SHALL NOT BE EXPOSED TO THE WEATHER. 7ALL GAS/WATER/SEWER/ELECTRIC LINES SHALL BE REMOVED OUT OF THE WAY BEFORE DEMOLITION BEGINS. FRAMING NOTES:FRAMING NOTES:1 ALL FRAMING WORK SHALL BE IN ACCORDANCE WITH THE LATESTEDITION OF THE MASSACHUSETTS RESIDENTIAL BUILDING CODE 9THEDITION CMR. 2 MARTIN DESIGNS MAKES NO CLAIMS TOWARDS EXISTINGCONDITIONS. 3 GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY BRACINGBEFORE AND DURING FRAMING.4 ALL SILL PLATES, WALL BASE AT GARAGE, BASEMENT, DECK &PORCH FRAMING SHALL BE PRESSURE TREATED. 5 ALL FRAMING LUMBER, BEAMS, JOISTS, RAFTERS, HEADERS, PLATESAND SILL SHALL BE SPRUCE PINE FIR #2 OR BETTER. 6 ALL LVL BEAMS SHALL BE VERSALAM BY BOISE CASCADE 2.0.7 ALL VERSALAM COLUMNS SHALL BE VERSA-LAM 1.8 BY BOISECASCADE.8 4 PLY LVL BEAMS SHALL BE SCREWED TOGETHER WITH SDWSSIMPSON SCREWS.9 ALL JOIST AND BEAM HANGERS SHALL BE SIMPSON.10 ALL WALL SHEATHING SHALL BE 1/2" CDX PLYWOOD.11 PLYWOOD SUBFLOORS SHALL BE TONGUE AND GROOVE, 3/4" THICK,A/C.12 EXTERIOR HEADERS SHALL BE 3 PLY 2x8s SPF #2 MINIMUM. INTERIORHEADERS SHALL BE 2 PLY 2x10s SPF #2 MINIMUM.13 HEADERS AND BEAMS SHALL BE SUPPORTED BY TWO JACK STUDAND ONE KING STUD.14 ALL EXTERIOR WALLS AND INTERIOR LOAD BEARING WALLS SHALLBE 2x6 @ 16" O.C. WITH 2 ROWS OF HORIZONTAL BLOCKING AT 1/3"POINTS.15 3/4 HOUR FIRE RESISTANCE RATING REQUIRED BETWEEN HOUSE &GARAGE CAN BE ACHIEVED WITH ONE LAYER OF 5/8" TYPE XDRYWALL ON GARAGE SIDE AND ONE LAYER 1/2" TYPE X DRYWALL ON THE HOUSE SIDE. 16 BLOCK IN BETWEEN ALL JOIST BAYS ROOF NOTES:ROOF NOTES:1 30 YEAR ASPHALT SHINGLES OR EQUAL2ALL ROOF SHEATHING SHALL BE 5/8" TONGUE AND GROOVE CDXPLYWOOD. 3 3'-0" WIDE ICE & WATER SHIELD AT ALL ROOF/WALL JUNCTIONS. 4 GENERAL CONTRACTOR TO PROVIDE FLASHING PERMANUFACTURER'S INSTALLATION REQUIREMENTS AT ALL ROOF/WALL JUNCTIONS.5 CONTINUOUS ROOF VENT TYPICAL. 6 ALUMINUM DRIP EDGE. 7 ALUMINUM GUTTERS & DOWNSPOUTS.8 1x8 FASCIA & SOFFIT WITH 2" CONTINUOUS VENT. 2x SUB-FASCIA.1X2 TRIM9USE SIMPSON HURRICANE CLIPS AS REQUIRED BYMASSACHUSETTS STATE BUILDING CODE.10 GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARYBRACING AND SHORING TO AVOID EXCESSIVE STRESSES ANDHOLD STRUCTURAL ELEMENTS IN PLACE DURINGCONSTRUCTION.11 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMEDWHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OFROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACHSEPARATE SPACE BY VENTILATING OPENINGS PROTECTEDAGAINST THE ENTRANCE OF RAIN AND/OR SNOW. 12 VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF1/16 INCH MINIMUM AND 1/4 INCH SHALL BE PROVIDED WITHCORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARECLOTH OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEASTDIMENSION OF 1/16 INCH MINIMUM AND 1/4 INCH MAXIMUM. FOR PROPER SCALE; THESE DRAWINGS SHOULD BE PRINTED ON ARCH D PAPER SIZE (24"x36") EXISTING SQUARE FOOTAGEEXISTING SQUARE FOOTAGE 1ST FLOOR: 1,136 SQ-FT E XIS TINGEXISTING PRO PO SEDPROPOSED DESIGN CRITERIA:DESIGN CRITERIA: 40 PSF LIVING AREA LIVE LOADS 30 PSF SLEEPING AREA LIVE LOADS 20 PSF UNINHABITABLE ATTIC LIVE LOADS 15 PSF ROOF DEAD LOAD 40 PSF ROOF SNOW LOAD 60 PSF BALCONIES AND DECKS LIVE LOADS WIND SPEED: 128 mph FROST WALL DEPTH: 4'-0" PROJECT NOTES:PROJECT NOTES:1.FINISH EXISTING BASEMENT 2.ADD FULL BATHROOM IN NEW BASEMENT 3.GUT AND RENOVATE ENTIRE 1ST FLOOR 4.ADD NEW MASTER SUITE TO 2ND FLOOR 5.ADD NEW REAR SHED DORMER ON 2ND FLOOR 6.ADD NEW REAR WOOD DECK 7.REPLACE ALL EXISTING WINDOWS AND DOORS 8.INSULATE ENTIRE HOUSE PER NEW CODE 9.ALL ELECTRICAL WORK SHALL BE DONE BY A LICENSED ELECTRICIAN 10.ALL PLUMBING WORK SHALL BE DONE BY A LICENSED PLUMBER 11.ALL HVAC WORK SHALL BE DONE BY A LICENSED TECHNICIAN 12.UPDATE ALL SMOKE & CO DETECTORS PROPOSED SQUARE FOOTAGEPROPOSED SQUARE FOOTAGE 1ST FLOOR: 1,136 SQ-FT 2ND FLOOR: 1,136 SQ-FT BASEMENT: 590 SQ-FT INSULATION NOTES:USE R-21 ON 2x EXTERIOR WALLSUSE R-49 ON ROOF (SPRAY FOAM CLOSED CELL) PROPOSED BARN FLOOR PLANS P.E. STAMP 6x8 Post 6x8 Post 6x8 Post 10'28'14'14'16'-4" 13' 13' 13' 13'10'10'8'-6"9'8'-6"4'-6"14'-11 3/4"10'WINDOW SCHEDULE 3 PLY 1-3/4" x 11-7/8" LVL DROPPED GARAGE HEADER 2x8 #2 S.P.F. CEILING JOISTS AT 16" O.C. 2x8 #2 S.P.F. CEILING JOISTS AT 16" O.C. 3 PLY 1-3/4" x 11-7/8" LVL DROPPED GARAGE HEADER FRAME PER PFH METHOD (4) 2x6 STUDS NAILED TOGETHER (4) 2x6 STUDS NAILED TOGETHER(4) 2x6 STUDS NAILED TOGETHER TRIPLE 2x10 #2 S.P.F.WINDOW HEADER3 PLY 1-3/4" x 11-7/8" LVL FLUSH BEAM 3 PLY 1-3/4" x 9-1/2" LVL FLUSH BEAM 3 PLY 1-3/4" x 9-1/2"LVL DOOR HEADER4x6 D.F. POST DN 4x6 D.F. POST DN3 PLY 1-3/4" x 9-1/2"LVL DOOR HEADERUSE LUS210 HANGERS USE LUS210 HANGERS TRIPLE 2x10 #2 S.P.F. DOOR HEADER TRIPLE 2x10 #2 S.P.F. WINDOW HEADER TRIPLE 2x10 #2 S.P.F. WINDOW HEADER 3 PLY 2x10 #2 S.P.F.DROPPED HEADER4 PLY 2x10 #2 S.P.F. DROPPED HEADER CATHEDRAL CEILING ABOVE3 PLY 2x12 #2 S.P.F.DROPPED HEADERTRIPLE 2x10 #2 S.P.F. WINDOW HEADER TRIPLE 2x10 #2 S.P.F. WINDOW HEADER 2x10 #2 S.P.F. FLOOR JOISTS AT 16" O.C. 2x10 #2 S.P.F. FLOOR JOISTS AT 16" O.C. BEARING WALL BELOW. BLOCK IN BETWEEN EVERY JOIST BAY.FRAME THIS WALL WITHSTUDS AT 12" O.C. WITH1/3 SPAN BLOCKING3 PLY 2x10 STAIR TRIMMER3 PLY 2x10 STAIR TRIMMERCANTILEVERTRIPLE 2x10 #2 S.P.F.DOOR HEADERTRIPLE 2x10 #2 S.P.F.DOOR HEADERTRIPLE 2x10 #2 S.P.F. WINDOW HEADER TRIPLE 2x10 #2 S.P.F. WINDOW HEADER (4) 2x6 STUDS NAILED TOGETHER (4) 2x6 STUDS NAILED TOGETHER (4) 2x6 STUDS NAILED TOGETHER FLOOR FRAMING PLAN 10'28'52' 26'ATTIC HATCHTRIPLE 2x10 #2 S.P.F. WINDOW HEADER TRIPLE 2x10 #2 S.P.F. WINDOW HEADER TRIPLE 2x10 #2 S.P.F. WINDOW HEADER TRIPLE 2x10 #2 S.P.F. WINDOW HEADER TRIPLE 2x10 #2 S.P.F. WINDOW HEADER TRIPLE 2x10 #2 S.P.F.WINDOW HEADERTRIPLE 2x10 #2 S.P.F.WINDOW HEADERTRIPLE 2x10 #2 S.P.F.WINDOW HEADERTRIPLE 2x10 #2 S.P.F.WINDOW HEADERTRIPLE 2x10 #2 S.P.F.WINDOW HEADERROOF TRUSSES ABOVE ROOF TRUSSES ABOVE 2x8 #2 S.P.F. CEILING JOISTS AT 16" O.C. CEILING FRAMING PLAN MAXIMUM ALLOWABLE SPAN CHART FOR SPRUCE-PINE-FIR #2 O.C. SPACING (INCHES) MEMBER SIZE FLOOR JOISTS 40psf LL / 10 psf DL / L/360 DEFLECTION CEILING JOISTS 20psf LL / 10 psf DL / L/240 DEFLECTION UNINHABITABLE ROOF RAFTERS 30psf GSL / 20 psf DL / L/180 DEFLECTION NOTES: LL = LIVE LOAD / DL = DEAD LOAD / GSL = GROUND SNOW LOAD THE ABOVE FLOOR JOIST TABLE IS BASED ON THE IRC 2018 TABLE R502.3.1(2) THE ABOVE CEILING JOIST TABLE IS BASED ON THE IRC 2018 TABLE R802.5.1(2) THE ABOVE ROOF RAFTER TABLE IS BASED ON THE IRC 2018 TABLE R802.4.1(3) FOUNDATION WALL FOOTING DETAIL NOT TO SCALE 10" FOUNDATION WALL 24"x10" FOUNDATION FOOTING w/ KEY STRIP FOOTING DETAIL NOT TO SCALE 24"x24" STRIP FOOTING LCE4 LCE4 POST CAP DETAIL NOT TO SCALE SIMPSON HANGER CONNECTION DETAIL NOT TO SCALE LUS SIMPSON HANGER SIMPSON HURRICANE CONNECTOR DETAIL NOT TO SCALE SIMPSON HURRICANE TIE H2.5A 2x RAFTER DOUBLE 2X TOP PLATE Exterior Wood Stair 5/4 x 6" DECKING 4 x 6 PRESSURE TREATED POST DECK RIM JOIST 2 x 12 STRINGER EQUALLY SPACED RISERS 8" MAX (check local code for requirements) EQUALLY SPACED RISERS 8" MAX (check local code for requirements) Interior Stair BASE MOLDING FINISH FLOORING PLYWOOD SUBFLOOR AT TREAD AND RISER FULL STRINGER SOFFIT BLOCKING NOTCHED STRINGER SIMPSON ABA66z DETAIL NOT TO SCALE 36" RAILINGSFINISHED SQ-FT 1ST FLOOR = 681 SQ-FT 2ND FLOOR = 908 SQ-FT TOTAL = 1,589 SQ-FT FAN FAN8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT FAN EGRESS EGRESS ATTIC ACCESS 24"x36" 2x6 BOTTOM CHORDS 12 6 12 6 2 x6 T O P C H O R D S 2 x 6 T OP C H OR DSSTORAGE 97-1/4" 109-1/4"3 PLY 2x10 HEADER 3 PLY 2x10 HEADER SOLE PLATE DOUBLE TOP PLATE CRIPPLE STUDS ROUGH OPENING TYP. TWO 2x6 JACK STUDS & ONE KING STUD CUT & REMOVED AFTER WALL IS ERECTED TWO 2x6 JACK STUDS & ONE KING STUD 2x6 1/3 SPAN BLOCKING 2x6 KD STUDS @ 16" O.C. TYPICAL WALL FRAMING DETAIL NOT TO SCALE 1ST FLOOR WALL ROUGH HEIGHT2ND FLOOR WALL ROUGH HEIGHT7/16" ZIP SHEATHING 2x6 PT SILL 1/2" DRYWALL INTERIOR FINISH 2x6 STUD FRAMING @ 16" O.C. R-30 INSULATED WALL CAVITY MEMBRANE VINYL SIDING 2x6 DOUBLE TOP PLATE EXTERIOR WALL DETAIL NOT TO SCALE FIREPLACE2x4 BEARING WALL 26' x 10' COVERED PORCH 260 SQ-FT FAN LINE OF WALL ABOVE 9'-0" CEILING HEIGHT 9'-0" CEILING HEIGHT WINDOW SCHEDULE NUMBER QTY FLOOR SIZE WIDTH HEIGHT R/O DESCRIPTION COMMENTS W01 1 1 2836DH 32 "42 "33"X43"DOUBLE HUNG W02 3 1 2840DH 32 "48 "33"X49"DOUBLE HUNG W03 10 2 2850DH 32 "60 "33"X61"DOUBLE HUNG W04 4 1 2860DH 32 "72 "33"X73"DOUBLE HUNG W05 1 2 5040FX 60 "48 "61"X49"FIXED GLASS LINE OF WALL ABOVE EV CHARGING PORT 15 Risers @ 8" 14 Treads @ 10" FINISHED 4" LALLY COLUMN w/ 6"x8" SPRINGFIELD PLATES ON 24"x24"x24" CONCRETE FOOTINGS. 4" LALLY COLUMN w/ 6"x8" SPRINGFIELD PLATES ON 24"x24"x24" CONCRETE FOOTINGS.36" min. RailingsSMOKE DETECTOR CARBON MONOXIDE DETECTOR HEAT DETECTOR NOTES: -ALL SMOKE DETECTORS SHALL BE PHOTOELECTRIC. -ALL CARBON MONOXIDE DETECTORS SHALL BE KIDDE PI2010. -ALL HEAT DETECTORS SHALL BE KIDDE FIREX HARDWIRED INTER-CONNECTABLE. SMOKE DETECTORS & CARBON MONOXIDE DETECTORS SMOKE DETECTORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: IN THE IMMEDIATE VICINITY OF BEDROOMS, ALL BEDROOMS ON EACH FLOOR INCLUDING BASEMENTS AND ATTICS. PHOTOELECTRIC SMOKE DETECTORS ANY SMOKE DETECTOR LOCATED WITHIN 20 FEET OF A KITCHEN OR WITHIN 20 FEET OF A BATHROOM CONTAINING A TUB OR A SHOWER SHALL BE PHOTOELECTRIC TYPE SMOKE DETECTORS. INSULATION NOTES: USE 2" RIGID INSULATION UNDER FOUNDATION SLAB USE R-30 ON 2x6 EXTERIOR WALLS (SPRAY FOAM ) USE R-30 ON GARAGE CEILING USE R-60 ON ROOF RAFTERS(SPRAY FOAM) DOOR AND WINDOW NOTES: EVERY BEDROOM SHALL BE PROVIDED WITH AN EGRESS WINDOW WITH FINISH SILL HEIGHT NOT GREATER THAN 44" ABOVE THE FINISH FLOOR HEIGHT AND SHALL HAVE A MINIMUM OPENABLE AREA OF 5.7 SQ. FT. EGRESS WINDOWS SHALL NOT HAVE AN OPENABLE AREA LESS THAN 20" WIDE OR 24" HIGH. MIN. U-VALUE OF 0.30. G.C. SHALL PROVIDE ALL WINDOW SPECS TO THE BUILDING DEPARTMENT. ALL WALK-THRU DOORS SHALL BE SOLID CORE INTERIOR DOORS SHALL BE PAINTED. ENTRY DOOR TO BE DEFINED BY HOME OWNER PRIOR ORDERING DOORS BETWEEN GARAGE AND LIVING AREA SHALL BE 1-3/4" TIGHT FITTING SOLID CORE DOORS WITH A RATING OF 60 MINUTES. DOOR SHALL BE SELF CLOSING EXTERIOR EXIT DOORS WILL BE 36" MIN. NET CLEAR DOORWAY SHALL BE 32" MIN. DOOR SHALL BE OPENABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. GLAZING IN DOORS SHALL BE DUAL PANE SAFETY GLASS WITH MIN. U-VALUE OF 0.30 GARAGE DOORS TO BE SECTIONAL, OVERHEAD DOORS REVISION TABLEDATEREVISED BYDESCRIPTIONMARTIN DESIGNSBELLINGHAM - MAMARTINDESIGNSINC@GMAIL.COMCLIENT INFORMATION:WILLIAM CAULDER1045 MAIN STCOTUIT - MASCALE: 3/8" = 1'-0" DATE: 8/27/2024 DISCLAIMER: THIS DRAWING IS FOR REPRESENTATION PURPOSES ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND TO CONFORM WITH LOCAL AND STATE BUILDING CODES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THE SAFETY AND PROPER BUILDING OF THE STRUCTURE REPRESENTED. THESE DRAWINGS HAVE BEEN REVIEWED BY A PROFESSIONAL ENGINEER IN THE STATE OF MASSACHUSETTS. ALL NEW CONSTRUCTION SHALL COMPLY WITH THE MASSACHUSETTS STATE BUILDING CODE 9TH EDITION CMR.COPYRIGHT: THESE DRAWINGS ARE EXCLUSIVE PROPERTY OF MARTIN DESIGNS. REPRODUCTION OF THESE PLANS IS STRICTLY PROHIBITED. A-4 PROPOSED FRAMING PLANS GENERAL NOTES:GENERAL NOTES: 1IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND LOCAL BUILDING CODES AND REQUIREMENTS. 2ALL NEW CONSTRUCTION SHALL COMPLY WITH THE MASSACHUSETTS STATE BUILDING CODE 9TH EDITION CMR. 3THE GENERAL CONTRACTOR SHALL REVIEW AND NOTIFY MARTIN DESIGNS OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK. 4THE GENERAL CONTRACTOR SHALL LEAVE THE PROJECT SITE CLEAR AT ALL TIMES AND REMOVE ALL DEBRIS. 5THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, PATCHING, CHASING, AND REPAIRING REQUIRED TO PERFORM THE WORK. 6IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WORK OF ALL TRADES. 7IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL ALL MATERIALS AND EQUIPMENT AS PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. 8DIMENSIONS ARE TO CENTER LINES, TO FACE OF FINISHED SURFACE, OR EXISTING BUILDING GRID LINES. 9THESE DRAWINGS ARE NOT TO BE SCALED FOR DIMENSIONS. 10THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL INSTALLATIONS, CONDITIONS, MATERIALS AND FINISHES WITH THE PROPOSED SCOPE OF WORK. 11THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION. 12THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING, PAYING, AND SCHEDULING INSPECTIONS AND PULLING PERMITS. 13ALL PENETRATIONS SHALL BE SEALED TIGHT WITH UL-LISTED FIRESTOPPING. 14ALL DATA OUTLETS MUST BE ON A DEDICATED, ISOLATED CIRCUIT. FOR PROPER SCALE; THESE DRAWINGS SHOULD BE PRINTED ON ARCH D PAPER SIZE (24"x36") P.E. STAMP 28'10'2'2'2'2' 2'2'2'10'9'10'9'2x12 RIDGE BOARD 10" OVERHANGS 2x10 #2 S.P.F. ROOF RAFTERS AT 16" O.C. USE H2.5A HURRICANE CLIPS ON EACH RAFTER 10" OVERHANGS USE H2.5A HURRICANE CLIPS ON EACH TRUSS 2x8 #2 S.P.F. ROOF RAFTERS AT 16" O.C. SCISSOR TRUSSES AT 24" O.C. 10" OVERHANGS 10" OVERHANGS STORAGE ROOF TRUSSES AT 24" O.C. USE H2.5A HURRICANE CLIPS ON EACH TRUSS USE H2.5A HURRICANE CLIPS ON EACH TRUSS 2x8 #2 S.P.F. ROOF RAFTERS AT 16" O.C. 10" OVERHANGS USE H2.5A HURRICANE CLIPS ON EACH RAFTER ATTICHATCHROOF FRAMING PLAN 3 : 123 : 126 : 126 : 123 / 12 INSIDESCISSORTRUSS PITCH3 / 12 INSIDESCISSORTRUSS PITCHRoof Plan View CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDERCUSTOM ORDER 31'6 / 12 3 / 12 6 / 1 2 3 / 1 2 TRIPLE 2x12 #2 S.P.F. BEAM 2x6 STUD WALL R-30 INSULATION R-60 INSULATION SCISSOR TRUSSES AT 24" O.C. ARCHITECTURAL ROOF SHINGLES OR EQUAL ON 5/8" ROOF SHEATHING 24"x24" STRIP FOOTING 6x8 SOLID POST 3 / 1 2 10" OVERHANG 4 PLY 2x10 #2 S.P.F. DROPPED HEADER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDER CUSTOM ORDERCUSTOM ORDER S-1 SECTION MAXIMUM ALLOWABLE SPAN CHART FOR SPRUCE-PINE-FIR #2 O.C. SPACING (INCHES) MEMBER SIZE FLOOR JOISTS 40psf LL / 10 psf DL / L/360 DEFLECTION CEILING JOISTS 20psf LL / 10 psf DL / L/240 DEFLECTION UNINHABITABLE ROOF RAFTERS 30psf GSL / 20 psf DL / L/180 DEFLECTION NOTES: LL = LIVE LOAD / DL = DEAD LOAD / GSL = GROUND SNOW LOAD THE ABOVE FLOOR JOIST TABLE IS BASED ON THE IRC 2018 TABLE R502.3.1(2) THE ABOVE CEILING JOIST TABLE IS BASED ON THE IRC 2018 TABLE R802.5.1(2) THE ABOVE ROOF RAFTER TABLE IS BASED ON THE IRC 2018 TABLE R802.4.1(3) FOUNDATION WALL FOOTING DETAIL NOT TO SCALE 10" FOUNDATION WALL 24"x10" FOUNDATION FOOTING w/ KEY STRIP FOOTING DETAIL NOT TO SCALE 24"x24" STRIP FOOTING LCE4 LCE4 POST CAP DETAIL NOT TO SCALE SIMPSON HANGER CONNECTION DETAIL NOT TO SCALE LUS SIMPSON HANGER SIMPSON HURRICANE CONNECTOR DETAIL NOT TO SCALE SIMPSON HURRICANE TIE H2.5A 2x RAFTER DOUBLE 2X TOP PLATE SIMPSON ABA66z DETAIL NOT TO SCALE 28'5'10'36" RAILINGSFINISHED SQ-FT 1ST FLOOR = 681 SQ-FT 2ND FLOOR = 908 SQ-FT TOTAL = 1,589 SQ-FT FAN FAN8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT FAN EGRESS EGRESS ATTIC ACCESS 24"x36" TRUSS NOTES: 1. ALL TRUSSES SHALL CARRY MANUFACTURERS STAMP. 2. ALL TRUSSES SHALL BE INSTALLED & BRACED TO MANUFACTURERS SPECIFICATIONS. 3. ALL TRUSSES WILL NOT BE FIELD ALTERED WITHOUT PRIOR BUILDING DEPT. APPROVAL OF ENGINEERING CALCULATIONS. 4. ALL TRUSSES SHALL HAVE DESIGN DETAILS & DRAWINGS PROVIDED BY TRUSS MANUFACTURER ON SITE FOR FRAMING INSPECTION. 5. NON BEARING WALLS SHOULD BE HELD DOWN FROM THE TRUSS BOTTOM CHORD W/ SIMPSON STC TO INSURE THAT THE TRUSS BOTTOM CHORD WILL NOT BEAR ON THE WALL. 6. ALL CONNECTIONS OF RAFTERS, JACK OR HIP TRUSSES TO MAIN GIRDER TO BE PROVIDED BY TRUSS MANUFACTURE. 7. ALL ROOF TRUSS FRAMING 24" O.C. 8. ALL ROOF TRUSS PITCH 6:12 9. STORAGE TRUSS ABOVE GARAGE. 10. TRUSSES MANUFACTURER TO PROVIDE TRUSS PROFILES 11. ALL OVERHANGS 10". 12. ROOF SNOW LOAD = 30psf DEAD LOAD = 20psf 13. ADD EXTRA 5psf DEAD LOAD FOR SOLAR PANELS ATTIC VENTILATION: AREA / 300 PROVIDE 1" MIN. AIR GAP AT EAVES WITH INSULATION BAFFLES TYP. AT ALL TRUSS BAYS. PROVIDE GABLE VENTS ALL GABLE ENDS. PROVIDE GALV. ROOF VENTS ON BACKSIDE OF ROOFLINE ABOVE CONDITIONED AREA. 2x6 BOTTOM CHORDS 12 6 12 6 2 x6 T O P C H O R D S 2 x 6 T OP C H OR DSSTORAGE MAXIMUM ALLOWABLE SPAN CHART FOR SPRUCE-PINE-FIR #2 2 X 6 12 16 24 O.C. SPACING (INCHES) MEMBER SIZE 2 X 8 2 X 10 2 X 12 12 16 24 12 16 24 12 16 24 FLOOR JOISTS 40psf LL / 10 psf DL / L/360 DEFLECTION CEILING JOISTS 20psf LL / 10 psf DL / L/240 DEFLECTION UNINHABITABLE ROOF RAFTERS 30psf GSL / 20 psf DL / L/180 DEFLECTION 12'-4" 10'-8" 8'-8" 15'-7" 13'-6" 11'-0" 19'-1" 16'-6" 13'-6" 22'-1" 19'-2" 15'-7" NOTES: LL = LIVE LOAD / DL = DEAD LOAD / GSL = GROUND SNOW LOAD THE ABOVE FLOOR JOIST TABLE IS BASED ON THE IRC 2018 TABLE R502.3.1(2) THE ABOVE CEILING JOIST TABLE IS BASED ON THE IRC 2018 TABLE R802.5.1(2) THE ABOVE ROOF RAFTER TABLE IS BASED ON THE IRC 2018 TABLE R802.4.1(3) 14'-9" 12'-10" 10'-6" 18'-9" 16'-3" 13'-3" 22'-11" 19'-10" 16'-3" -- -- -- 10'-3" 9'-4" 8'-1" 13'-6" 12'-3" 10'-3" 17'-3" 15'-5" 12'-7" 20'-7" 17'-10" 14'-7" FOUNDATION WALL FOOTING DETAIL NOT TO SCALE 10" FOUNDATION WALL 24"x10" FOUNDATION FOOTING w/ KEY STRIP FOOTING DETAIL NOT TO SCALE 24"x24" STRIP FOOTING LCE4 LCE4 POST CAP DETAIL NOT TO SCALE SIMPSON HANGER CONNECTION DETAIL NOT TO SCALE LUS SIMPSON HANGER SIMPSON HURRICANE CONNECTOR DETAIL NOT TO SCALE SIMPSON HURRICANE TIE H2.5A 2x RAFTER DOUBLE 2X TOP PLATE SIMPSON ABA66z DETAIL NOT TO SCALE 36" RAILINGSFINISHED SQ-FT 1ST FLOOR = 681 SQ-FT 2ND FLOOR = 908 SQ-FT TOTAL = 1,589 SQ-FT FAN FAN8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT FAN EGRESS EGRESS ATTIC ACCESS 24"x36" 2x6 BOTTOM CHORDS 12 6 12 6 2x6 TOP CHORDS2 x 6 T OP C HOR D SSTORAGE REVISION TABLEDATEREVISED BYDESCRIPTIONMARTIN DESIGNSBELLINGHAM - MAMARTINDESIGNSINC@GMAIL.COMCLIENT INFORMATION:WILLIAM CAULDER1045 MAIN STCOTUIT - MASCALE: 3/8" = 1'-0" DATE: 8/27/2024 DISCLAIMER: THIS DRAWING IS FOR REPRESENTATION PURPOSES ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND TO CONFORM WITH LOCAL AND STATE BUILDING CODES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THE SAFETY AND PROPER BUILDING OF THE STRUCTURE REPRESENTED. THESE DRAWINGS HAVE BEEN REVIEWED BY A PROFESSIONAL ENGINEER IN THE STATE OF MASSACHUSETTS. ALL NEW CONSTRUCTION SHALL COMPLY WITH THE MASSACHUSETTS STATE BUILDING CODE 9TH EDITION CMR.COPYRIGHT: THESE DRAWINGS ARE EXCLUSIVE PROPERTY OF MARTIN DESIGNS. REPRODUCTION OF THESE PLANS IS STRICTLY PROHIBITED. FOR PROPER SCALE; THESE DRAWINGS SHOULD BE PRINTED ON ARCH D PAPER SIZE (24"x36") GENERAL NOTES:GENERAL NOTES:1 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND LOCALBUILDING CODES AND REQUIREMENTS. 2 ALL NEW CONSTRUCTION SHALL COMPLY WITH THE MASSACHUSETTS STATE BUILDING CODE 9TH EDITION CMR. 3 THE GENERAL CONTRACTOR SHALL REVIEW AND NOTIFY MARTIN DESIGNS OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK. 4 THE GENERAL CONTRACTOR SHALL LEAVE THE PROJECT SITE CLEAR AT ALL TIMES AND REMOVE ALL DEBRIS. 5 THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, PATCHING, CHASING, AND REPAIRING REQUIRED TO PERFORM THE WORK. 6 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WORK OF ALL TRADES. 7 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL ALL MATERIALS AND EQUIPMENT AS PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. 8 DIMENSIONS ARE TO CENTER LINES, TO FACE OF FINISHED SURFACE, OR EXISTING BUILDING GRID LINES. 9 THESE DRAWINGS ARE NOT TO BE SCALED FOR DIMENSIONS. 10 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL INSTALLATIONS, CONDITIONS, MATERIALS AND FINISHES WITH THE PROPOSED SCOPE OF WORK. 11 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION. 12 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING, PAYING, AND SCHEDULING INSPECTIONS AND PULLING PERMITS. 13 ALL PENETRATIONS SHALL BE SEALED TIGHT WITH UL-LISTED FIRESTOPPING. 14 ALL DATA OUTLETS MUST BE ON A DEDICATED, ISOLATED CIRCUIT. A-5 FRAMING PLANS / SECTION SQUARE FOOTAGESQUARE FOOTAGE 1ST FLOOR: 1,636 SQ-FT 2ND FLOOR: 1,886 SQ-FT TOTAL: 3,522 SQ-FT C U S T O M E R R E V I E W F I N A LCUSTOMER R E V I E W F I N A L FRAMING NOTES:FRAMING NOTES: 1 ALL FRAMING WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE MASSACHUSETTS RESIDENTIAL BUILDING CODE 9TH EDITION CMR. 2 MARTIN DESIGNS MAKES NO CLAIMS TOWARDS EXISTING CONDITIONS. 3 GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY BRACING BEFORE AND DURING FRAMING. 4 ALL SILL PLATES, WALL BASE AT GARAGE, BASEMENT, DECK & PORCH FRAMING SHALL BE PRESSURE TREATED. 5 ALL FRAMING LUMBER, BEAMS, JOISTS, RAFTERS, HEADERS, PLATES AND SILL SHALL BE SPRUCE PINE FIR #2 OR BETTER. 6 ALL LVL BEAMS SHALL BE VERSALAM BY BOISE CASCADE 7 ALL SOLID COLUMNS SHALL HAVE POST CAPS. 8 ALL EXTERIOR HARDWARE SHALL BE GALVANIZED 9 ALL JOIST AND BEAM HANGERS SHALL BE SIMPSON. 10 ALL WALL SHEATHING SHALL BE 1/2" CDX PLYWOOD OR 7/16" ZIP SHEATHING 11 PLYWOOD SUBFLOORS SHALL BE TONGUE AND GROOVE, 3/4" THICK, A/C. 12 EXTERIOR HEADERS SHALL BE 2 PLY 2x8s SPF #2 MINIMUM. INTERIOR HEADERS SHALL BE 2 PLY 2x8s SPF #2 MINIMUM. 13 HEADERS AND BEAMS SHALL BE SUPPORTED BY TWO JACK STUD AND ONE KING STUD. 14 ALL EXTERIOR WALLS AND INTERIOR LOAD BEARING WALLS SHALL BE 2x6 @ 16" O.C. WITH 2 ROWS OF HORIZONTAL BLOCKING AT 1/3" POINTS. ROOF NOTES:ROOF NOTES: 1 ARCHITECTURAL ROOF SHINGLES OR EQUAL, BLEND TO EXISTING. 2 ALL ROOF SHEATHING SHALL BE 5/8" TONGUE AND GROOVE CDX PLYWOOD. 3 3'-0" WIDE ICE & WATER SHIELD AT ALL ROOF/WALL JUNCTIONS. 4 GENERAL CONTRACTOR TO PROVIDE FLASHING PER MANUFACTURER'S INSTALLATION REQUIREMENTS AT ALL ROOF/WALL JUNCTIONS. 5 CONTINUOUS ROOF VENT TYPICAL. 6 ALUMINUM DRIP EDGE. 7 ALUMINUM GUTTERS & DOWNSPOUTS. 8 1x8 FASCIA & SOFFIT WITH 2" CONTINUOUS VENT. 2x SUB- FASCIA. 1X2 TRIM 9 USE SIMPSON HURRICANE CLIPS AS REQUIRED BY MASSACHUSETTS STATE BUILDING CODE. 10 GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING AND SHORING TO AVOID EXCESSIVE STRESSES AND HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. 11 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN AND/OR SNOW. 12 VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF 1/16 INCH MINIMUM AND 1/4 INCH SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16 INCH MINIMUM AND 1/4 INCH MAXIMUM. P.E. STAMP